Temperature characteristics of nitinol spiral stents A Bezrouk, J Hanus, J Záhora Scr. Med.(Brno) 78 (4), 219-226, 2005 | 41* | 2005 |
Models of stents-Comparison and applications J Zahora, A Bezrouk, J Hanus Physiological research 56 (1), S115, 2007 | 40 | 2007 |
Tolerability and outcomes of kinetically guided therapy with gentamicin in critically ill neonates during the first week of life: an open-label, prospective study J Martínková, P Pokorná, J Záhora, J Chládek, V Vobruba, ... Clinical therapeutics 32 (14), 2400-2414, 2010 | 34 | 2010 |
Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice A Bezrouk, L Balsky, M Smutny, IS Krulichova, J Zahora, J Hanus, ... American Journal of Orthodontics and Dentofacial Orthopedics 146 (3), 319-327, 2014 | 22 | 2014 |
On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians J Hanus, T Nosek, J Zahora, A Bezrouk, V Masin Physica Medica 29 (1), 83-90, 2013 | 13 | 2013 |
SMST 2003: proceedings of the international conference on shape memory and superelastic technologies AR Pelton ASM International, 2004 | 13 | 2004 |
Measurement and comparison of mechanical properties of nitinol stents J Hanus, J Zahora Physica Scripta 2005 (T118), 264, 2005 | 12 | 2005 |
Temperature characteristics of nitinol spiral stents A Bezrouk, J Hanus, J Záhora Scripta Med (Brno) 78, 219-226, 2005 | 11 | 2005 |
Thermo-mechanical properties of NiTi closed coil springs–force degradation and force regeneration over time, viscous properties A Bezrouk, L Balský, M Smutný, T Nosek, J Záhora, J Hanuš, R Polma Acta Medica 56 (2), 41-46, 2015 | 9 | 2015 |
On-line incorporation of study and medical information system in undergraduate medical education J Hanus, J Záhora, V Masin, A Bezrouk ICERI2013 Proceedings, 1500-1507, 2013 | 7 | 2013 |
Remotely Controlled Laboratory and Virtual Experiments in Teaching Medical Biophysics J Zahora, J Hanus, D Jezbera, A Bezrouk ICERI2013 Proceedings, 900-906, 2013 | 6 | 2013 |
Biopsie sentinelové uzliny u karcinomu prsu v klinické praxi J Gatěk, L Hnátek, B Dudešek, P Vážan, J Bakala, K Hradská, J Kotoč, ... Rozhledy v chirurgii: měsíčník Československé chirurgické společnosti, 2008 | 5 | 2008 |
Measurement of mechanical properties of stents J Hanus, J Zahora Proceedings, XVII IMEKO World Congress, TC13, 1731-1733, 2003 | 3 | 2003 |
Nickel-titanium closed-coil springs: evaluation of the clinical plateau A Bezrouk, L Balsky, IS Krulichova, M Smutny, J Zahora, GW Selke, ... Rev. Chim 68 (5), 1137-1142, 2017 | 2 | 2017 |
Clearance of gentamicin in asphyxiated neonates undergoing modest therapeutic whole-body hypothermia J Záhora, J Martínková, P Pokorná, J Chládek, V Vobruba BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY 105, 150-150, 2009 | 2 | 2009 |
Automated data acquisition and FEM virtual experiments in teaching medical biophysics J Zahora, J Hanus, V Masin, A Bezrouk Proceedings of the 10th IASTED International Conference on Computers and …, 2008 | 2 | 2008 |
Therapeutic drug monitoring (TDM) of gentamicin in critically ill neonate I Selke-Krulichova, J Martinkova, P Pokorna, J Zahora Biomedical Papers 151, 84-86, 2007 | 2 | 2007 |
Software for practical training in medical biophysics J Zahora, J Hanus Recent Advances in Multidisciplinary Applied Physics, 149-154, 2005 | 2 | 2005 |
Design of nitinol stents J Zahora, J Hanus SMST-2004 Proceedings of International Conference on Shape Memory and …, 2004 | 2 | 2004 |
Model of mechanical properties of nitinol stent J Zahora, J Hanus rn 1, 0, 2003 | 2 | 2003 |