Segui
Quan Chen
Quan Chen
Professor, Radiation Oncology, Mayo Clinic Arizona
Email verificata su uky.edu
Titolo
Citata da
Citata da
Anno
Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
W Lu, GH Olivera, Q Chen, KJ Ruchala, J Haimerl, SL Meeks, KM Langen, ...
Physics in Medicine & Biology 51 (17), 4357, 2006
2122006
Objective assessment of deformable image registration in radiotherapy: a multi‐institution study
R Kashani, M Hub, JM Balter, ML Kessler, L Dong, L Zhang, L Xing, Y Xie, ...
Medical physics 35 (12), 5944-5953, 2008
1812008
Ultrasound monitoring of temperature change during radiofrequency ablation: preliminary in-vivo results
T Varghese, JA Zagzebski, Q Chen, U Techavipoo, G Frank, C Johnson, ...
Ultrasound in medicine & biology 28 (3), 321-329, 2002
1812002
Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses
U Techavipoo, T Varghese, Q Chen, TA Stiles, JA Zagzebski, GR Frank
The Journal of the Acoustical Society of America 115 (6), 2859-2865, 2004
1612004
Elastographic imaging of in vivo soft tissue
T Varghese, JA Zagzebski, U Techavipoo, Q Chen
US Patent 7,166,075, 2007
1572007
System and method for motion adaptive optimization for radiation therapy delivery
W Lu, M Chen, Q Chen, KJ Ruchala, GH Olivera
US Patent 8,509,383, 2013
1532013
A simple fixed‐point approach to invert a deformation field a
M Chen, W Lu, Q Chen, KJ Ruchala, GH Olivera
Medical physics 35 (1), 81-88, 2008
1462008
Automatic re-contouring in 4D radiotherapy
W Lu, GH Olivera, Q Chen, ML Chen, KJ Ruchala
Physics in Medicine & Biology 51 (5), 1077, 2006
1462006
Estimation of displacement vectors and strain tensors in elastography using angular insonifications
U Techavipoo, Q Chen, T Varghese, JA Zagzebski
IEEE transactions on medical imaging 23 (12), 1479-1489, 2004
1382004
Deep convolutional neural network for segmentation of thoracic organs‐at‐risk using cropped 3D images
X Feng, K Qing, NJ Tustison, CH Meyer, Q Chen
Medical physics 46 (5), 2169-2180, 2019
1252019
Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation
T Varghese, U Techavipoo, W Liu, JA Zagzebski, Q Chen, G Frank, ...
American journal of roentgenology 181 (3), 701-707, 2003
1202003
Pressure-dependent attenuation in ultrasound contrast agents
Q Chen, J Zagzebski, T Wilson, T Stiles
Ultrasound in medicine & biology 28 (8), 1041-1051, 2002
972002
Noise reduction using spatial-angular compounding for elastography
T Udomchai, Q Chen, T Varghese, JA Zagzebski, EL Madsen
ieee transactions on ultrasonics, ferroelectrics, and frequency control 51 …, 2004
772004
Normal and shear strain estimation using beam steering on linear-array transducers
M Rao, Q Chen, H Shi, T Varghese, EL Madsen, JA Zagzebski, TA Wilson
Ultrasound in medicine & biology 33 (1), 57-66, 2007
682007
Phantomless patient‐specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation
LL Handsfield, R Jones, DD Wilson, JV Siebers, PW Read, Q Chen
Medical physics 41 (10), 101703, 2014
652014
System and method of detecting a breathing phase of a patient receiving radiation therapy
W Lu, KJ Ruchala, M Chen, Q Chen, GH Olivera
US Patent 8,229,068, 2012
612012
Non-voxel-based broad-beam (NVBB) algorithm for intensity modulated radiation therapy dose calculation and plan optimization
W Lu, M Chen, Q Chen, KJ Ruchala
US Patent 8,401,148, 2013
602013
The ultrasonix 500RP: A commercial ultrasound research interface
T Wilson, J Zagzebski, T Varghese, Q Chen, M Rao
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 53 …, 2006
602006
Method for adapting fractionation of a radiation therapy dose
W Lu, M Chen, Q Chen, KJ Ruchala, GH Olivera
US Patent 8,222,616, 2012
592012
Parallel/opposed: IMRT QA using treatment log files is superior to conventional measurement‐based method
N Childress, Q Chen, Y Rong
Journal of applied clinical medical physics 16 (1), 4, 2015
582015
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–20