Segui
Andrius Petrėnas
Andrius Petrėnas
Research Fellow at Biomedical Engineering Institute, Kaunas University of Technology
Email verificata su ktu.lt
Titolo
Citata da
Citata da
Anno
A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings
V Marozas, A Petrenas, S Daukantas, A Lukosevicius
Journal of electrocardiology 44 (2), 189-194, 2011
1622011
Low-complexity detection of atrial fibrillation in continuous long-term monitoring
A Petrėnas, V Marozas, L Sörnmo
Computers in biology and medicine 65, 184-191, 2015
1392015
An echo state neural network for QRST cancellation during atrial fibrillation
A Petrenas, V Marozas, L Sornmo, A Lukosevicius
IEEE transactions on biomedical engineering 59 (10), 2950-2957, 2012
932012
Photoplethysmography-based method for automatic detection of premature ventricular contractions
A Sološenko, A Petrėnas, V Marozas
IEEE transactions on biomedical circuits and systems 9 (5), 662-669, 2015
852015
Modeling of the photoplethysmogram during atrial fibrillation
A Sološenko, A Petrėnas, V Marozas, L Sörnmo
Computers in biology and medicine 81, 130-138, 2017
802017
Detection of occult paroxysmal atrial fibrillation
A Petrėnas, L Sörnmo, A Lukoševičius, V Marozas
Medical & biological engineering & computing 53, 287-297, 2015
772015
Atrial fibrillation from an engineering perspective
A Petrėnas, V Marozas
Springer, 2018
502018
Detection of atrial fibrillation using a wrist-worn device
A Sološenko, A Petrėnas, B Paliakaitė, L Sörnmo, V Marozas
Physiological measurement 40 (2), 025003, 2019
482019
Electrocardiogram modeling during paroxysmal atrial fibrillation: application to the detection of brief episodes
A Petrenas, V Marozas, A Sološenko, R Kubilius, J Skibarkiene, J Oster, ...
Physiological measurement 38 (11), 2058, 2017
352017
Considerations on performance evaluation of atrial fibrillation detectors
M Butkuvienė, A Petrėnas, A Sološenko, A Martín-Yebra, V Marozas, ...
IEEE Transactions on Biomedical Engineering 68 (11), 3250-3260, 2021
342021
Model-based assessment of f-wave signal quality in patients with atrial fibrillation
M Henriksson, A Petrėnas, V Marozas, F Sandberg, L Sörnmo
IEEE Transactions on Biomedical Engineering 65 (11), 2600-2611, 2018
342018
A modified Lewis ECG lead system for ambulatory monitoring of atrial arrhythmias
A Petrėnas, V Marozas, G Jaruševičius, L Sörnmo
Journal of electrocardiology 48 (2), 157-163, 2015
322015
Estimation of heart rate recovery after stair climbing using a wrist-worn device
D Sokas, A Petrėnas, S Daukantas, A Rapalis, B Paliakaitė, V Marozas
Sensors 19 (9), 2113, 2019
192019
Modeling and estimation of temporal episode patterns in paroxysmal atrial fibrillation
M Henriksson, A Martín-Yebra, M Butkuvienė, JG Rasmussen, V Marozas, ...
IEEE Transactions on Biomedical Engineering 68 (1), 319-329, 2020
172020
Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias
B Paliakaitė, A Petrėnas, A Sološenko, V Marozas
Biomedical Signal Processing and Control 66, 102421, 2021
162021
Detection of walk tests in free-living activities using a wrist-worn device
D Sokas, B Paliakaitė, A Rapalis, V Marozas, R Bailón, A Petrėnas
Frontiers in physiology 12, 706545, 2021
142021
Towards pulse rate parametrization during free-living activities using smart wristband
A Rapalis, A Petrėnas, M Šimaitytė, R Bailon, V Marozas
Physiological Measurement 39 (5), 055007, 2018
142018
Model for simulating ECG and PPG signals with arrhythmia episodes
A Sološenko, A Petrėnas, B Paliakaitė, V Marozas, L Sörnmo
PhysioNet, 2021
132021
Detection of atrial fibrillation
L Sörnmo, A Petrėnas, V Marozas
Atrial Fibrillation from an Engineering Perspective, 73-135, 2018
132018
High specificity wearable device with photoplethysmography and six-lead electrocardiography for atrial fibrillation detection challenged by frequent premature contractions …
J Bacevicius, Z Abramikas, E Dvinelis, D Audzijoniene, M Petrylaite, ...
Frontiers in cardiovascular medicine 9, 869730, 2022
122022
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–20