Feasibility and safety of using a fused echocardiography/fluoroscopy imaging system in patients with congenital heart disease PN Jone, MM Ross, JA Bracken, MJ Mulvahill, MV Di Maria, TE Fagan Journal of the American Society of Echocardiography 29 (6), 513-521, 2016 | 65 | 2016 |
Multimodality 3-dimensional image integration for congenital cardiac catheterization TE Fagan, UT Truong, PN Jone, J Bracken, R Quaife, AAA Hazeem, ... Methodist DeBakey cardiovascular journal 10 (2), 68, 2014 | 65 | 2014 |
Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation C Coolens, J Bracken, B Driscoll, A Hope, D Jaffray Medical physics 39 (5), 2669-2681, 2012 | 35 | 2012 |
Diagnostic utility of three-dimensional rotational angiography in congenital cardiac catheterization O Aldoss, BM Fonseca, UT Truong, J Bracken, JR Darst, R Guo, TL Jones, ... Pediatric cardiology 37, 1211-1221, 2016 | 29 | 2016 |
Integrated 3D echo-x ray to optimize image guidance for structural heart intervention SD Clegg, SJ Chen, N Nijhof, MS Kim, EE Salcedo, RA Quaife, ... Cardiovascular Imaging 8 (3), 371-374, 2015 | 23 | 2015 |
Design, performance, and applications of a hybrid X-Ray/MR system for interventional guidance R Fahrig, A Ganguly, P Lillaney, J Bracken, JA Rowlands, Z Wen, H Yu, ... Proceedings of the IEEE 96 (3), 468-480, 2008 | 23 | 2008 |
Intracavity wavelength conversions employing a MgO-doped LiNbO3 quasi-phase-matched waveguide and an erbium-doped fiber amplifier CQ Xu, J Bracken, B Chen JOSA B 20 (10), 2142-2149, 2003 | 20 | 2003 |
Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: a prospective study P Nicholson, NM Cancelliere, J Bracken, E Hummel, F van Nijnatten, ... European Journal of Radiology 138, 109645, 2021 | 17 | 2021 |
A radiation dose reduction technology to improve patient safety during cardiac catheterization interventions JA Bracken, M Mauti, MS Kim, JC Messenger, JD Carroll Journal of Interventional Cardiology 28 (5), 493-497, 2015 | 16 | 2015 |
Closed bore XMR (CBXMR) systems for aortic valve replacement: Active magnetic shielding of x‐ray tubes JA Bracken, G DeCrescenzo, P Komljenovic, PV Lillaney, R Fahrig, ... Medical physics 36 (5), 1717-1726, 2009 | 13 | 2009 |
Integrated 3D Echo-X-Ray navigation to predict optimal angiographic deployment projections for TAVR MS Kim, J Bracken, N Nijhof, EE Salcedo, RA Quaife, JC Messenger, ... JACC: Cardiovascular Imaging 7 (8), 847-848, 2014 | 12 | 2014 |
Closed‐bore XMR (CBXMR) systems for aortic valve replacement: X‐ray tube imaging performance JA Bracken, P Komljenovic, PV Lillaney, R Fahrig, JA Rowlands Medical physics 36 (4), 1086-1097, 2009 | 12 | 2009 |
All-optical wavelength conversions based on MgO-doped LiNbO3 QPM waveguides using an EDFA as a pump source JA Bracken, CQ Xu IEEE Photonics Technology Letters 15 (7), 954-956, 2003 | 10 | 2003 |
Multimodality 3-dimensional image integration for congenital cardiac catheterization. Methodist Debakey Cardiovasc J. 2014; 10 (2): 68–76 TE Fagan, UT Truong, PN Jone, J Bracken, R Quaife, AA Hazeem, ... This study gives an overview on how fusion imaging can be used for planing …, 0 | 7 | |
Device for modifying an imaging of a tee probe in X-ray data JA Bracken, N Nijhof, M Grass US Patent 11,850,083, 2023 | 5 | 2023 |
Automated probe steering to clinical views using annotations in a fused image guidance system JA Bracken, DP Noonan, A Popovic | 5 | 2020 |
Closed bore XMR (CBXMR) systems for aortic valve replacement: Investigation of rotating‐anode x‐ray tube heat loadability JA Bracken, PV Lillaney, R Fahrig, JA Rowlands Medical physics 35 (9), 4049-4062, 2008 | 4 | 2008 |
O-005 New cone beam CT assessment of acute stroke patients: are we ready for prime time? N Cancelliere, T Grunhagen, J Bracken, F Nijnatten, T Krings, VM Pereira Journal of NeuroInterventional Surgery 10 (Suppl 2), A6-A7, 2018 | 3 | 2018 |
Development of an MR compatible rotating anode x-ray tube P Lillaney, J Bracken, A Ganguly, J Rowlands, R Fahrig Medical Imaging 2008: Physics of Medical Imaging 6913, 1332-1341, 2008 | 3 | 2008 |
Analysis of all-optical intra-cavity wavelength conversions in fiber ring resonators B Chen, J Bracken, F Verleyen, Y Wang, C Xu Optics communications 247 (1-3), 57-64, 2005 | 3 | 2005 |