Follow
Tomohiro Kobayashi
Tomohiro Kobayashi
Verified email at arch.eng.osaka-u.ac.jp
Title
Cited by
Cited by
Year
Experimental investigation and CFD analysis of cross-ventilated flow through single room detached house model
T Kobayashi, M Sandberg, H Kotani, L Claesson
Building and Environment 45 (12), 2723-2734, 2010
702010
Numerical investigation and accuracy verification of indoor environment for an impinging jet ventilated room using computational fluid dynamics
T Kobayashi, K Sugita, N Umemiya, T Kishimoto, M Sandberg
Building and Environment 115, 251-268, 2017
532017
Stream tube based analysis of problems in prediction of cross-ventilation rate
T Kobayashi, K Sagara, T Yamanaka, H Kotani, S Takeda, M Sandberg
International Journal of Ventilation 7 (4), 321-334, 2009
382009
Evaluation of ventilation performance of monitor roof in residential area based on simplified estimation and CFD analysis
T Kobayashi, T Chikamoto, K Osada
Building and environment 63, 20-30, 2013
352013
Effect of supply velocity and heat generation density on cooling and ventilation effectiveness in room with impinging jet ventilation system
H Yamasawa, T Kobayashi, T Yamanaka, N Choi, M Cehlin, A Ameen
Building and Environment 205, 108299, 2021
332021
Wind driven flow through openings-analysis of the stream tube
T Kobayashi, K Sagara, T Yamanaka, H Kotani, M Sandberg
International journal of ventilation 4 (4), 323-336, 2006
322006
Experimental investigation of difference in indoor environment using impinging jet ventilation and displacement ventilation systems
H Yamasawa, T Kobayashi, T Yamanaka, N Choi, M Matsuzaki
International Journal of Ventilation 21 (3), 229-246, 2022
232022
Applicability of displacement ventilation and impinging jet ventilation system to heating operation
H Yamasawa, T Kobayashi, T Yamanaka, N Choi, M Cehlin, A Ameen
Japan Architectural Review 4 (2), 403-416, 2021
192021
Numerical analysis of wind-induced natural ventilation for an isolated cubic room with two openings under small mean wind pressure difference
T Kobayashi, M Sandberg, T Fujita, E Lim, N Umemiya
Building and Environment 226, 109694, 2022
182022
Evaluation of outdoor thermal comfort under different building external-wall-surface with different reflective directional properties using CFD analysis and model experiment
J Yuan, S Masuko, Y Shimazaki, T Yamanaka, T Kobayashi
Building and Environment 207, 108478, 2022
182022
Prediction of thermal and contaminant environment in a room with impinging jet ventilation system by zonal model
H Yamasawa, T Kobayashi, T Yamanaka, N Choi, M Cehlin, A Ameen
Building and Environment 221, 109298, 2022
172022
Influence of vertical airflow along walls on temperature and contaminant concentration distributions in a displacement-ventilated four-bed hospital ward
N Choi, T Yamanaka, T Kobayashi, T Ihama, M Wakasa
Building and Environment 183, 107181, 2020
172020
A literature review of cross ventilation in buildings
Z Jiang, T Kobayashi, T Yamanaka, M Sandberg
Energy and Buildings, 113143, 2023
162023
Validity of Orifice equation and impact of building parameters on wind-induced natural ventilation rates with minute mean wind pressure difference
Z Jiang, T Kobayashi, T Yamanaka, M Sandberg, N Kobayashi, N Choi, ...
Building and Environment 219, 109248, 2022
162022
我が国における建物の自然換気及び通風に関する研究の 130 年の歴史
小林知広
日本建築学会環境系論文集 83 (751), 749-759, 2018
14*2018
Impact of indoor aroma on students’ mood and learning performance
N Choi, T Yamanaka, A Takemura, T Kobayashi, A Eto, M Hirano
Building and Environment 223, 109490, 2022
132022
Ventilation performance of monitor roof provided for a pitched-roof detached house
T Kobayashi, T Yamanaka, H Kotani, K Sagara, Y Maruhashi, S Tanabe
Journal of Environmental Engineering(Transaction of AIJ) 75 (653), 595-601, 2010
13*2010
Power transportation inside stream tube of cross-ventilated simple shaped model and pitched roof house
T Kobayashi, K Sagara, T Yamanaka, H Kotani, M Sandberg
Building and environment 44 (7), 1440-1451, 2009
132009
Numerical investigation of the flow behavior of an isothermal corner impinging jet for building ventilation
A Ameen, M Cehlin, U Larsson, H Yamasawa, T Kobayashi
Building and Environment 223, 109486, 2022
122022
Simplified prediction using block model for vertical profile of temperature and contaminant concentration in a room with impinging jet ventilation
T Kobayashi, N Umemiya
Building and Environment 209, 108643, 2022
122022