FDA benchmark medical device flow models for CFD validation RA Malinauskas, P Hariharan, SW Day, LH Herbertson, M Buesen, ... Asaio Journal 63 (2), 150-160, 2017 | 154 | 2017 |
A computational method for predicting inferior vena cava filter performance on a patient-specific basis KI Aycock, RL Campbell, KB Manning, SP Sastry, SM Shontz, FC Lynch, ... Journal of biomechanical engineering 136 (8), 081003, 2014 | 41 | 2014 |
Inter-laboratory characterization of the velocity field in the FDA blood pump model using particle image velocimetry (PIV) P Hariharan, KI Aycock, M Buesen, SW Day, BC Good, LH Herbertson, ... Cardiovascular engineering and technology 9, 623-640, 2018 | 40 | 2018 |
The importance of hemorheology and patient anatomy on the hemodynamics in the inferior vena cava KI Aycock, RL Campbell, FC Lynch, KB Manning, BA Craven Annals of biomedical engineering 44, 3568-3582, 2016 | 37 | 2016 |
Particle image velocimetry measurements in an anatomical vascular model fabricated using inkjet 3D printing KI Aycock, P Hariharan, BA Craven Experiments in Fluids 58, 1-8, 2017 | 33 | 2017 |
A resolved two-way coupled CFD/6-DOF approach for predicting embolus transport and the embolus-trapping efficiency of IVC filters KI Aycock, RL Campbell, KB Manning, BA Craven Biomechanics and Modeling in Mechanobiology 16, 851-869, 2017 | 32 | 2017 |
Steady flow in a patient-averaged inferior vena cava—Part II: Computational fluid dynamics verification and validation BA Craven, KI Aycock, KB Manning Cardiovascular Engineering and Technology 9, 654-673, 2018 | 31 | 2018 |
A CFD-based Kriging surrogate modeling approach for predicting device-specific hemolysis power law coefficients in blood-contacting medical devices BA Craven, KI Aycock, LH Herbertson, RA Malinauskas Biomechanics and Modeling in Mechanobiology 18, 1005-1030, 2019 | 29 | 2019 |
Steady flow in a patient-averaged inferior vena cava—Part I: Particle image velocimetry measurements at rest and exercise conditions MB Gallagher, KI Aycock, BA Craven, KB Manning Cardiovascular engineering and technology 9, 641-653, 2018 | 22 | 2018 |
Full-field microscale strain measurements of a nitinol medical device using digital image correlation KI Aycock, JD Weaver, HM Paranjape, K Senthilnathan, C Bonsignore, ... Journal of the Mechanical Behavior of Biomedical Materials 114, 104221, 2021 | 18 | 2021 |
An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC E Tedaldi, C Montanari, KI Aycock, F Sturla, A Redaelli, KB Manning Medical Engineering & Physics 54, 44-55, 2018 | 18 | 2018 |
Computational predictions of the embolus-trapping performance of an IVC filter in patient-specific and idealized IVC geometries KI Aycock, RL Campbell, FC Lynch, KB Manning, BA Craven Biomechanics and Modeling in Mechanobiology 16, 1957-1969, 2017 | 17 | 2017 |
A probabilistic approach with built-in uncertainty quantification for the calibration of a superelastic constitutive model from full-field strain data HM Paranjape, KI Aycock, C Bonsignore, JD Weaver, BA Craven, ... Computational Materials Science 192, 110357, 2021 | 16 | 2021 |
Rotary bend fatigue of nitinol to one billion cycles JD Weaver, GM Sena, KI Aycock, A Roiko, WM Falk, S Sivan, BT Berg Shape Memory and Superelasticity 9 (1), 50-73, 2023 | 10 | 2023 |
Method of manufactured solutions code verification of elastostatic solid mechanics problems in a commercial finite element solver KI Aycock, N Rebelo, BA Craven Computers & Structures 229, 106175, 2020 | 7 | 2020 |
In Vitro Clot Trapping Efficiency of the FDA Generic Inferior Vena Cava Filter in an Anatomical Model: An Experimental Fluid–Structure Interaction Benchmark JM Riley, NS Price, HM Saaid, BC Good, KI Aycock, BA Craven, ... Cardiovascular engineering and technology 12, 339-352, 2021 | 5 | 2021 |
A sharp interface Lagrangian-Eulerian method for flexible-body fluid-structure interaction EM Kolahdouz, DR Wells, S Rossi, KI Aycock, BA Craven, BE Griffith Journal of Computational Physics 488, 112174, 2023 | 4 | 2023 |
Two Calculation Verification Metrics Used in the Medical Device Industry: Revisiting the Limitations of Fractional Change I Guler, KI Aycock, N Rebelo Journal of Verification, Validation and Uncertainty Quantification 7 (3), 031004, 2022 | 4 | 2022 |
A Poisson equation method for prescribing fully developed non-Newtonian inlet conditions for computational fluid dynamics simulations in models of arbitrary cross-section BA Craven, MM Faghih, KI Aycock, EM Kolahdouz Mathematics and Computers in Simulation 194, 523-538, 2022 | 2 | 2022 |
Two-Step Uncertainty Quantification Methodology for Medical Device Design: Influence of Input Parameter Probability Distribution on Output Uncertainty I Carr, K Aycock, C Bonsignore, H Paranjape, J Weaver, B Craven Bulletin of the American Physical Society, 2023 | 1 | 2023 |