Visual acuities and scotomas after one week levodopa administration in human amblyopia. I Gottlob, J Charlier, RD Reinecke Investigative ophthalmology & visual science 33 (9), 2722-2728, 1992 | 107 | 1992 |
New instrument for monitoring eye fixation and pupil size during the visual field examination JR Charlier, JC Hache Medical and Biological Engineering and Computing 20, 23-28, 1982 | 45 | 1982 |
Optokinetic nystagmus in patients with central scotomas in age related macular degeneration C Valmaggia, J Charlier, I Gottlob British journal of ophthalmology 85 (2), 169-172, 2001 | 32 | 2001 |
Museum application of an eye tracker C Buquet, JR Charlier, V Paris Medical and Biological Engineering and Computing 26, 277-281, 1988 | 29 | 1988 |
Quantitative assessment of the static properties of the oculo-motor system by the photo-oculographic technique C Buquet, JR Charlier Medical and Biological Engineering and Computing 32, 197-204, 1994 | 28 | 1994 |
Operant conditioning of the visual smooth pursuit in young infants JC Darcheville, L Madelain, C Buquet, J Charlier, Y Miossec Behavioural Processes 46 (2), 131-139, 1999 | 27 | 1999 |
Clinical and functional evaluation of a gaze controlled system for the severely handicapped P Thoumie, JR Charlier, M Alecki, D d'Erceville, A Heurtin, JF Mathe, ... Spinal Cord 36 (2), 104-109, 1998 | 26 | 1998 |
Static flicker perimetry in glaucoma and ocular hypertension JG Feghali, X Bocquet, J Charlier, JV Odom Current eye research 10 (3), 205-212, 1991 | 25 | 1991 |
The development of visual pursuit during the first months of life D Lengyel, S Weinacht, J Charlier, I Gottlob Graefe's archive for clinical and experimental ophthalmology 236, 440-444, 1998 | 23 | 1998 |
Shift of the pupil center with pupil constriction JR Charlier, M Behague, C Buquet Investigative Ophthalmology and Visual Science 35 (4), 1278, 1994 | 19 | 1994 |
Eye-controlled microscope for surgical applications J Charlier, P Sourdille, M Behague, C Buquet Developments in ophthalmology 22, 154-158, 1991 | 15 | 1991 |
Real time pattern recognition and feature analysis from video signals applied to eye movement and pupillary reflex monitoring JR Charlier, JL Bariseau, V Chuffart, F Marsy, JC Hache Sixth International Visual Field Symposium: Santa Margherita Ligure, May 27 …, 1985 | 12 | 1985 |
Asymmetry of visual perceptive activity of faces and emotional facial expressions P Gallois, C Buquet, J Charlier, V Paris, JC Hache, JF Dereux Revue Neurologique 145 (8-9), 661-664, 1989 | 11 | 1989 |
COMPARISON OF AUTOMATED KINETIC AND STATIC VISUAL FIELDS IN NEURO-OPHTHALMOLOGY PATIENTS JACQUES R. CHARLIER’, SABINE DEFOORT2, JEAN FRANCOIS ROULAND2 and JEAN CLAUDE HACHE2 JR CHARLIER, S DEFOORT Perimetry update 89, 3-8, 1988 | 10 | 1988 |
Refixation strategies in four patients with macular disorders F Duret, C Buquet, J Charlier, C Mermoud, P Viviani, AB Safran Neuro-Ophthalmology 22 (4), 209-220, 1999 | 9 | 1999 |
VISIOBOARD: a new gaze command system for handicapped subjects J Charlier, C Buquet, F Dubus, JP Hugeux, B Degroc Medical and Biological Engineering and Computing 35 (416), 433-436, 1997 | 9 | 1997 |
Evaluation of sensory visual development based on measures of oculomotor responses C Buquet, J Charlier F. Vital-Durand, J. Atkinson, & OJ Braddick III, Infant 6ision, 291-306, 1996 | 9 | 1996 |
Sensibilité au contraste spatiale et âge X Zanlonghi, J Charlier, N Chevalier BULLETIN-SOCIETES D OPHTALMOLOGIE DE FRANCE 92, 921-921, 1992 | 9 | 1992 |
Application de la technique photo-oculographique à l'étude de la poursuite visuelle au cours des premiers mois de la vie J Charlier, C Buquet, A Desmidt, D Querleu Bulletin des sociétés d'ophtalmologie de France 93 (11), 973-978, 1993 | 8 | 1993 |
Method of automatic control of means for adjusting an apparatus for observing a subject, means for performing the method, and apparatus equipped with these means P Sourdille, J Charlier US Patent 5,094,522, 1992 | 8 | 1992 |