Ryan Willing
Ryan Willing
Email verificata su uwo.ca
Titolo
Citata da
Citata da
Anno
Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis
N Razfar, JM Reeves, DG Langohr, R Willing, GS Athwal, JA Johnson
Journal of shoulder and elbow surgery 25 (7), 1076-1083, 2016
572016
Design optimization of a total knee replacement for improved constraint and flexion kinematics
R Willing, IY Kim
Journal of biomechanics 44 (6), 1014-1020, 2011
532011
A holistic numerical model to predict strain hardening and damage of UHMWPE under multiple total knee replacement kinematics and experimental validation
R Willing, IY Kim
Journal of biomechanics 42 (15), 2520-2527, 2009
522009
Three dimensional shape optimization of total knee replacements for reduced wear
R Willing, IY Kim
Structural and Multidisciplinary Optimization 38 (4), 405-414, 2009
522009
Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter
GDG Langohr, R Willing, JB Medley, GS Athwal, JA Johnson
Journal of shoulder and elbow surgery 25 (4), 589-597, 2016
402016
Accuracy assessment of 3D bone reconstructions using CT: an intro comparison
EA Lalone, RT Willing, HL Shannon, GJW King, JA Johnson
Medical engineering & physics 37 (8), 729-738, 2015
392015
Validation of a finite element model of the human elbow for determining cartilage contact mechanics
RT Willing, EA Lalone, H Shannon, JA Johnson, GJW King
Journal of biomechanics 46 (10), 1767-1771, 2013
372013
The effect of distal humeral hemiarthroplasty on articular contact of the elbow
M Lapner, R Willing, JA Johnson, GJW King
Clinical Biomechanics 29 (5), 537-544, 2014
242014
Total hip wear assessment: a comparison between computational and in vitro wear assessment techniques using ISO 14242 loading and kinematics
G Matsoukas, R Willing, IY Kim
Journal of biomechanical engineering 131 (4), 2009
222009
Effect of radial head implant shape on joint contact area and location during static loading
HL Shannon, SR Deluce, EA Lalone, R Willing, GJW King, JA Johnson
The Journal of Hand Surgery 40 (4), 716-722, 2015
202015
Identifying the location and volume of bony impingement in elbow osteoarthritis by 3-dimensional computational modeling
M Nishiwaki, R Willing, JA Johnson, GJW King, GS Athwal
The Journal of Hand Surgery 38 (7), 1370-1376, 2013
182013
Development of a computational technique to measure cartilage contact area
R Willing, M Lapner, EA Lalone, GJW King, JA Johnson
Journal of Biomechanics 47 (5), 1193-1197, 2014
172014
Quantifying the competing relationship between durability and kinematics of total knee replacements using multiobjective design optimization and validated computational models
R Willing, IY Kim
Journal of biomechanics 45 (1), 141-147, 2012
162012
Quantifying the competing relationship between adduction range of motion and baseplate micromotion with lateralization of reverse total shoulder arthroplasty
J Elwell, J Choi, R Willing
Journal of biomechanics 52, 24-30, 2017
152017
Contact analysis of the native radiocapitellar joint compared with axisymmetric and nonaxisymmetric radial head hemiarthroplasty
GDG Langohr, R Willing, JB Medley, GJW King, JA Johnson
Journal of Shoulder and Elbow Surgery 24 (5), 787-795, 2015
152015
In vitro assessment of the contact mechanics of reverse-engineered distal humeral hemiarthroplasty prostheses
R Willing, M Lapner, GJW King, JA Johnson
Clinical Biomechanics 29 (9), 990-996, 2014
132014
A smart knee implant using triboelectric energy harvesters
A Ibrahim, M Jain, E Salman, R Willing, S Towfighian
Smart Materials and Structures 28 (2), 025040, 2019
122019
Osseous anatomy of the distal radioulnar joint: an assessment using 3-dimensional modeling and clinical implications
P Daneshvar, R Willing, M Pahuta, R Grewal, GJW King
The Journal of Hand Surgery 41 (11), 1071-1079, 2016
122016
A three-dimensional analysis of zygomatic symmetry in normal, uninjured faces
A Belcastro, R Willing, T Jenkyn, M Johnson, K Galil, A Yazdani
Journal of Craniofacial Surgery 27 (2), 504-508, 2016
122016
Regional variations in cartilage thickness of the radial head: implications for prosthesis design
C Yeung, S Deluce, R Willing, M Johnson, GJW King, GS Athwal
The Journal of hand surgery 40 (12), 2364-2371. e1, 2015
122015
Il sistema al momento non pu eseguire l'operazione. Riprova pi tardi.
Articoli 1–20