Follow
Valentina Aloisi
Valentina Aloisi
Verified email at phd.unipd.it
Title
Cited by
Cited by
Year
Influence of surface roughness on computed tomography dimensional measurements
S Carmignato, V Aloisi, F Medeossi, F Zanini, E Savio
CIRP Annals-Manufacturing Technology, 2017
632017
Influence of surface roughness on X-ray computed tomography dimensional measurements of additive manufactured parts
V Aloisi, S Carmignato
Case Studies in Nondestructive Testing and Evaluation 6, 104-110, 2016
632016
Principles of X-ray Computed Tomography
P Hermanek, JS Rathore, V Aloisi, S Carmignato
Industrial X-Ray Computed Tomography, 25-67, 2018
472018
Investigation on the effects of X-ray CT system geometrical misalignments on dimensional measurement errors
V Aloisi, S Carmignato, J Schlecht, E Ferley
7th conference on industrial computed tomography (iCT), 7-9, 2017
112017
Investigation on metrological performances in CT helical scanning for dimensional quality control
V Aloisi, S Carmignato, J Schlecht, E Ferley
6th Conference on Industrial Computed Tomography, Wels, Austria, 2016
112016
X-ray computed tomography instrument performance evaluation: Detecting geometry errors using a calibrated artifact
B Muralikrishnan, M Shilling, S Phillips, W Ren, V Lee, F Kim, G Alberts, ...
Dimensional Optical Metrology and Inspection for Practical Applications VIII …, 2019
82019
Characterization of the effects of detector angular misalignments and accuracy enhancement of X-ray CT dimensional measurements
V Aloisi, J Schlecht, E Ferley, S Carmignato
9th conference on industrial computed tomography (iCT), Padova, Italy, 2019
62019
Experimental investigation on the influence of detector misalignment on X-ray CT measurement accuracy
V Aloisi, S Carmignato, J Schlecht, E Ferley, E Savio
euspen’s 17th International Conference & Exhibition, Hannover, DE, May 2017, 2017
52017
Effect of surface roughness on uncertainty of X-ray CT dimensional measurements of additive manufactured parts
V Aloisi, S Carmignato, E Savio
euspen’s 15 th International Conference & Exhibition, Leuven, Belgium, June 2015, 2015
32015
Industrial X-ray computed tomography: accuracy enhancement and errors evaluation towards traceability of coordinate measurements
V Aloisi
12017
Computed Tomography Helical Scanning for Dimensional Metrology: Evaluation of Measurement Errors
V Aloisi, S Carmignato, J Schlecht, E Ferley
Materials Evaluation 74 (7), 1055-1059, 2016
12016
Investigation on scan parameters for accurate dimensional measurements by CT helical scanning
V Aloisi, S Carmignato, J Schlecht, E Ferley, E Savio
euspen’s 16 th International Conference & Exhibition, Nottingham, UK, May 2016, 2016
12016
Evaluating the use of industrial X-ray CT for the reverse engineering of bowed stringed instruments
F Piasentini, A Scanavini, S Carmignato, V Aloisi, M Rigodanza
2016
Investigation on the effects of surface roughness on X-ray CT dimensional measurements
V Aloisi, S Carmignato
Digital Industrial Radiology and Computed Tomography (DIR), Ghent, Belgium …, 2015
2015
The system can't perform the operation now. Try again later.
Articles 1–14