Follow
Alexander Gundlach-Graham
Title
Cited by
Cited by
Year
Single-particle multi-element fingerprinting (spMEF) using inductively-coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) to identify engineered nanoparticles against …
A Praetorius, A Gundlach-Graham, E Goldberg, W Fabienke, ...
Environmental Science: Nano 4 (2), 307-314, 2017
1832017
Characterization of a new ICP-TOFMS instrument with continuous and discrete introduction of solutions
L Hendriks, A Gundlach-Graham, B Hattendorf, D Günther
Journal of Analytical Atomic Spectrometry 32 (3), 548-561, 2017
1332017
Toward faster and higher resolution LA–ICPMS imaging: on the co-evolution of LA cell design and ICPMS instrumentation
A Gundlach-Graham, D Günther
Analytical and bioanalytical chemistry 408, 2687-2695, 2016
902016
High-speed, high-resolution, multielemental laser ablation-inductively coupled plasma-time-of-flight mass spectrometry imaging: part I. Instrumentation and two-dimensional …
A Gundlach-Graham, M Burger, S Allner, G Schwarz, HAO Wang, L Gyr, ...
Analytical chemistry 87 (16), 8250-8258, 2015
802015
High-speed, high-resolution, multielemental LA-ICP-TOFMS imaging: Part II. Critical evaluation of quantitative three-dimensional imaging of major, minor, and trace elements in …
M Burger, A Gundlach-Graham, S Allner, G Schwarz, HAO Wang, L Gyr, ...
Analytical chemistry 87 (16), 8259-8267, 2015
762015
Monte Carlo simulation of low-count signals in time-of-flight mass spectrometry and its application to single-particle detection
A Gundlach-Graham, L Hendriks, K Mehrabi, D Günther
Analytical chemistry 90 (20), 11847-11855, 2018
602018
Single-particle ICP-MS with online microdroplet calibration: toward matrix independent nanoparticle sizing
L Hendriks, B Ramkorun-Schmidt, A Gundlach-Graham, J Koch, ...
Journal of Analytical Atomic Spectrometry 34 (4), 716-728, 2019
572019
Single-particle ICP-TOFMS with online microdroplet calibration for the simultaneous quantification of diverse nanoparticles in complex matrices
K Mehrabi, D Günther, A Gundlach-Graham
Environmental Science: Nano 6 (11), 3349-3358, 2019
532019
Capabilities of laser ablation inductively coupled plasma time-of-flight mass spectrometry
M Burger, G Schwarz, A Gundlach-Graham, D Käser, B Hattendorf, ...
Journal of Analytical Atomic Spectrometry 32 (10), 1946-1959, 2017
512017
Method for enhancement of mass resolution over a limited mass range for time-of-flight spectrometry
CG Enke, SJ Ray, AW Graham, GM Hieftje, E Dennis, CJ Barinaga, ...
US Patent 8,604,423, 2013
432013
Performance of sp-ICP-TOFMS with signal distributions fitted to a compound Poisson model
L Hendriks, A Gundlach-Graham, D Günther
Journal of Analytical Atomic Spectrometry 34 (9), 1900-1909, 2019
412019
Analysis of inorganic nanoparticles by single-particle inductively coupled plasma time-of-flight mass spectrometry
L Hendriks, A Gundlach-Graham, D Günther
Chimia 72 (4), 221-221, 2018
382018
Monodisperse microdroplets: a tool that advances single-particle ICP-MS measurements
A Gundlach-Graham, K Mehrabi
Journal of Analytical Atomic Spectrometry 35 (9), 1727-1739, 2020
352020
Resolution and mass range performance in distance-of-flight mass spectrometry with a multichannel focal-plane camera detector
GM Hieftje, CG Enke, AW Graham, SJ Ray, E Dennis, CJ Barinaga, ...
US Patent App. 14/110,998, 2014
342014
Emerging investigator series: automated single-nanoparticle quantification and classification: a holistic study of particles into and out of wastewater treatment plants in …
K Mehrabi, R Kaegi, D Günther, A Gundlach-Graham
Environmental Science: Nano 8 (5), 1211-1225, 2021
332021
Combined distance-of-flight and time-of-flight mass spectrometer
CG Enke, SJ Ray, AW Graham, GM Hieftje, CJ Barinaga, DW Koppenaal
US Patent 8,648,295, 2014
302014
First distance-of-flight instrument: opening a new paradigm in mass spectrometry
AWG Graham, SJ Ray, CG Enke, CJ Barinaga, DW Koppenaal, ...
Journal of the American Society for Mass Spectrometry 22 (1), 110-117, 2011
292011
High‐resolution, quantitative element imaging of an upper crust, low‐angle Cataclasite (Zuccale Fault, Northern Apennines) by laser ablation ICP time‐of‐flight mass spectrometry
A Gundlach‐Graham, PS Garofalo, G Schwarz, D Redi, D Günther
Geostandards and Geoanalytical Research 42 (4), 559-574, 2018
282018
Replacing the argon ICP: Nitrogen microwave inductively coupled atmospheric-pressure plasma (MICAP) for mass spectrometry
M Schild, A Gundlach-Graham, A Menon, J Jevtic, V Pikelja, M Tanner, ...
Analytical chemistry 90 (22), 13443-13450, 2018
262018
Characterization of inductively coupled plasma time-of-flight mass spectrometry in combination with collision/reaction cell technology–insights from highly time-resolved …
M Burger, L Hendriks, J Kaeslin, A Gundlach-Graham, B Hattendorf, ...
Journal of Analytical Atomic Spectrometry 34 (1), 135-146, 2019
232019
The system can't perform the operation now. Try again later.
Articles 1–20