Follow
Jaime Shaw
Jaime Shaw
Inari Medical
Verified email at cshs.org
Title
Cited by
Cited by
Year
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
AG Christodoulou, JL Shaw, C Nguyen, Q Yang, Y Xie, N Wang, D Li
Nature biomedical engineering 2 (4), 215-226, 2018
3172018
Free‐breathing, non‐ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking
JL Shaw, Q Yang, Z Zhou, Z Deng, C Nguyen, D Li, AG Christodoulou
Magnetic resonance in medicine 81 (4), 2450-2463, 2019
852019
Optimized CEST cardiovascular magnetic resonance for assessment of metabolic activity in the heart
Z Zhou, C Nguyen, Y Chen, JL Shaw, Z Deng, Y Xie, J Dawkins, ...
Journal of cardiovascular magnetic resonance 19, 1-7, 2017
452017
Chemical exchange saturation transfer fingerprinting for exchange rate quantification
Z Zhou, P Han, B Zhou, AG Christodoulou, JL Shaw, Z Deng, D Li
Magnetic resonance in medicine 80 (4), 1352-1363, 2018
442018
Scar heterogeneity on cardiovascular magnetic resonance as a predictor of appropriate implantable cardioverter defibrillator therapy
H Rayatzadeh, A Tan, RH Chan, SJ Patel, TH Hauser, L Ngo, JL Shaw, ...
Journal of Cardiovascular Magnetic Resonance 15, 1-7, 2013
352013
Free‐breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size
MH Moghari, RH Chan, SN Hong, JL Shaw, LA Goepfert, KV Kissinger, ...
Magnetic Resonance in Medicine 68 (6), 1866-1875, 2012
342012
Myocardial tissue deformation is reduced in subjects with coronary microvascular dysfunction but not rescued by treatment with ranolazine
MD Nelson, B Sharif, JL Shaw, G Cook‐Wiens, J Wei, C Shufelt, ...
Clinical cardiology 40 (5), 300-306, 2017
282017
Deep Learning Within a Priori Temporal Feature Spaces for Large-Scale Dynamic MR Image Reconstruction: Application to 5-D Cardiac MR Multitasking
Y Chen, JL Shaw, Y Xie, D Li, AG Christodoulou
Medical Image Computing and Computer Assisted Intervention–MICCAI 2019: 22nd …, 2019
232019
Volumetric left ventricular ejection fraction is superior to 2-dimensional echocardiography for risk stratification of patients for primary prevention implantable cardioverter …
H Rayatzadeh, SJ Patel, TH Hauser, LL Ngo, JL Shaw, A Tan, AE Buxton, ...
The American journal of cardiology 111 (8), 1175-1179, 2013
202013
Respiratory bellows‐gated late gadolinium enhancement of the left atrium
DC Peters, JL Shaw, BR Knowles, MH Moghari, WJ Manning
Journal of Magnetic Resonance Imaging 38 (5), 1210-1214, 2013
192013
Left atrial late gadolinium enhancement with water–fat separation: The importance of phase‐encoding order
JL Shaw, BR Knowles, JW Goldfarb, WJ Manning, DC Peters
Journal of Magnetic Resonance Imaging 40 (1), 119-125, 2014
182014
Improved multimodality data fusion of late gadolinium enhancement MRI to left ventricular voltage maps in ventricular tachycardia ablation
S Roujol, TA Basha, A Tan, V Khanna, RH Chan, MH Moghari, ...
IEEE Transactions on Biomedical Engineering 60 (5), 1308-1317, 2012
172012
Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: development and feasibility study on the thoracic aorta
Z Hu, AG Christodoulou, N Wang, JL Shaw, SS Song, MM Maya, ...
Magnetic resonance in medicine 84 (5), 2376-2388, 2020
162020
Inverse association of MRI-derived native myocardial T1 and perfusion reserve index in women with evidence of ischemia and no obstructive CAD: a pilot study
JL Shaw, MD Nelson, J Wei, M Motwani, S Landes, PK Mehta, ...
International journal of cardiology 270, 48-53, 2018
132018
Low-rank tensor imaging for multidimensional cardiovascular MRI
D Li, AG Christodoulou, S Jaime, Y Xie, C Nguyen
US Patent 10,436,871, 2019
122019
A general low-rank tensor framework for high-dimensional cardiac imaging: Application to time-resolved T1 mapping
AG Christodoulou, JL Shaw, B Sharif, D Li
24th Annual Meeting of ISMRM, Singapore, 2016
122016
Improved fat water separation with water selective inversion pulse for inversion recovery imaging in cardiac MRI
L Havla, T Basha, H Rayatzadeh, JL Shaw, WJ Manning, SB Reeder, ...
Journal of Magnetic Resonance Imaging 37 (2), 484-490, 2013
112013
Guideline adherence for echocardiographic follow-up in outpatients with at least moderate valvular disease
RH Chan, JL Shaw, TH Hauser, LJ Markson, WJ Manning
Journal of the American Society of Echocardiography 28 (7), 795-801, 2015
102015
Method and apparatus for image enhancement in magnetic resonance imaging using motion corrupted data
M Akcakaya, JL Shaw, R Nezafat, S Roujol
US Patent 9,202,272, 2015
82015
Scar heterogeneity on cardiac magnetic resonance imaging is a predictor of appropriate implantable cardioverter defibrillator therapy: 10 years of experience
H Rayatzadeh, A Tan, T Hauser, J Shaw, S Patel, S Hong, R Chan, ...
Journal of the American College of Cardiology 59 (13S), E1081-E1081, 2012
52012
The system can't perform the operation now. Try again later.
Articles 1–20