Segui
Ning Jiang
Ning Jiang
West China Hospital, Sichuan University
Email verificata su ieee.org
Titolo
Citata da
Citata da
Anno
The extraction of neural information from the surface EMG for the control of upper-limb prostheses: emerging avenues and challenges
D Farina, N Jiang, H Rehbaum, A Holobar, B Graimann, H Dietl, ...
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (4 …, 2014
9592014
Myoelectric Control of Artificial Limbs?? Is There a Need to Change Focus?[In the Spotlight]
N Jiang, S Dosen, KR Muller, D Farina
Signal Processing Magazine, IEEE 29 (5), 152-150, 2012
5442012
Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal
N Jiang, KB Englehart, PA Parker
Biomedical Engineering, IEEE Transactions on 56 (4), 1070-1080, 2009
5042009
Linear and nonlinear regression techniques for simultaneous and proportional myoelectric control
JM Hahne, F Biessmann, N Jiang, H Rehbaum, D Farina, FC Meinecke, ...
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (2 …, 2014
4012014
Man/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation
D Farina, I Vujaklija, M Sartori, T Kapelner, F Negro, N Jiang, ...
Nature biomedical engineering 1 (2), 0025, 2017
3552017
Simultaneous and proportional force estimation for multifunction myoelectric prostheses using mirrored bilateral training
JLG Nielsen, S Holmgaard, N Jiang, KB Englehart, D Farina, PA Parker
Biomedical Engineering, IEEE Transactions on 58 (3), 681-688, 2011
334*2011
Intuitive, Online, Simultaneous and Proportional Myoelectric Control Over Two Degrees of Freedom in Upper Limb Amputees.
N Jiang, H Rehbaum, I Vujaklija, B Graimann, D Farina
IEEE transactions on neural systems and rehabilitation engineering: a …, 2013
3042013
Detection of movement intention from single-trial movement-related cortical potentials
IK Niazi, N Jiang, O Tiberghien, JF Nielsen, K Dremstrup, D Farina
Journal of Neural Engineering 8, 066009, 2011
2812011
Enhanced Low-latency Detection of Motor Intention from EEG for Closed-loop Brain-Computer Interface Applications
R Xu, N Jiang, C Lin, N Mrachacz-Kersting, K Dremstrup, D Farina
IEEE Transactions on Biomedical Engineering, 1-1, 2013
2432013
Efficient neuroplasticity induction in chronic stroke patients by an associative brain-computer interface
N Mrachacz-Kersting, N Jiang, A Stevenson, I Niazi, V Kostic, A Pavlovic, ...
Journal of Neurophysiology 115 (3), 1410-1421, 2016
2422016
Is accurate mapping of EMG signals on kinematics needed for precise online myoelectric control?
N Jiang, I Vujaklija, H Rehbaum, B Graimann, D Farina
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (3 …, 2013
2262013
Self-correcting pattern recognition system of surface EMG signals for upper limb prosthesis control
S Amsüss, PM Goebel, N Jiang, B Graimann, L Paredes, D Farina
IEEE Transactions on Biomedical Engineering 61 (4), 1167-1176, 2014
2222014
Extracting Signals Robust to Electrode Number and Shift for Online Simultaneous and Proportional Myoelectric Control by Factorization Algorithms
S Muceli, N Jiang, D Farina
IEEE Transaction on Neural Systems and Rehabilitation Engineering, 1-1, 2013
2072013
EMG-based simultaneous and proportional estimation of wrist/hand dynamics in uni-Lateral trans-radial amputees
N Jiang, JLG Vest-Nielsen, S Muceli, D Farina, A Prasad, M Sahin, ...
Journal of NeuroEngineering and Rehabilitation 9 (1), 42, 2012
2072012
Influence of the training set on the accuracy of surface EMG classification in dynamic contractions for the control of multifunction prostheses
T Lorrain, N Jiang, D Farina
Journal of neuroengineering and rehabilitation 8 (1), 25, 2011
1962011
A closed-loop brain–computer interface triggering an active ankle–foot orthosis for inducing cortical neural plasticity
R Xu, N Jiang, N Mrachacz-Kersting, C Lin, GA Prieto, JC Moreno, ...
IEEE Transactions on Biomedical Engineering 61 (7), 2092-2101, 2014
1842014
User adaptation in long-term, open-loop myoelectric training: implications for EMG pattern recognition in prosthesis control
J He, D Zhang, N Jiang, X Sheng, D Farina, X Zhu
Journal of neural engineering 12 (4), 046005, 2015
1652015
A brain–computer interface for single-trial detection of gait initiation from movement related cortical potentials
N Jiang, L Gizzi, N Mrachacz-Kersting, K Dremstrup, D Farina
Clinical Neurophysiology 126 (1), 154-159, 2015
1582015
Peripheral Electrical Stimulation Triggered by Self-Pace Detection of Motor Intention Enhances Motor Evoked Potentials
IK Niazi, N Mrachacz-Kersting, N Jiang, K Nielsen, D Farina
IEEE Transactions on Neural System and Rehabilitation Engineering, 1-1, 2012
1582012
Effect of arm position on the prediction of kinematics from EMG in amputees
N Jiang, S Muceli, B Graimann, D Farina
Medical and Biological Engineering and Computing 51 (1), 143-151, 2013
1382013
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–20