Xiang Feng
Xiang Feng
MR Solutions Ltd
Verified email at mrsolutions.com
Title
Cited by
Cited by
Year
A comprehensive numerical analysis of background phase correction with V‐SHARP
PS Özbay, A Deistung, X Feng, D Nanz, JR Reichenbach, F Schweser
NMR in Biomedicine 30 (4), e3550, 2017
342017
The influence of brain iron and myelin on magnetic susceptibility and effective transverse relaxation-A biochemical and histological validation study
S Hametner, V Endmayr, A Deistung, P Palmrich, M Prihoda, ...
Neuroimage 179, 117-133, 2018
312018
Quantitative susceptibility mapping (QSM) and R2* in the human brain at 3 T: Evaluation of intra-scanner repeatability
X Feng, A Deistung, JR Reichenbach
Zeitschrift für Medizinische Physik 28 (1), 36-48, 2018
252018
An improved FSL-FIRST pipeline for subcortical gray matter segmentation to study abnormal brain anatomy using quantitative susceptibility mapping (QSM)
X Feng, A Deistung, MG Dwyer, J Hagemeier, P Polak, J Lebenberg, ...
Magnetic resonance imaging 39, 110-122, 2017
162017
Accelerated magnetic resonance imaging using the sparsity of multi-channel coil images
G Xie, Y Song, C Shi, X Feng, H Zheng, D Weng, B Qiu, X Liu
Magnetic resonance imaging 32 (2), 175-183, 2014
112014
Methods for the computation of templates from quantitative magnetic susceptibility maps (QSM): Toward improved atlas‐and voxel‐based analyses (VBA)
J Hanspach, MG Dwyer, NP Bergsland, X Feng, J Hagemeier, N Bertolino, ...
Journal of Magnetic Resonance Imaging 46 (5), 1474-1484, 2017
102017
A robust algorithm for high-resolution dynamic MRI based on the partially separable functions model
X Feng, G Xie, S He, B Kou, C Zou, H Zheng, X Liu, B Qiu
Magnetic Resonance Imaging 30 (5), 620-626, 2012
42012
Histogram analysis of 11C-methionine integrated PET/MRI may facilitate to determine the O6-methylguanylmethyltransferase methylation status in gliomas
P Yu, J Ning, B Xu, J Liu, H Dang, M Lin, X Feng, R Grimm, J Tian
Nuclear medicine communications 40 (8), 850-856, 2019
32019
Toward a voxel-based analysis (VBA) of quantitative magnetic susceptibility maps (QSM): Strategies for creating brain susceptibility templates
J Hanspach, MG Dwyer, NP Bergsland, X Feng, J Hagemeier, P Polak, ...
Proc Intl Soc Mag Reson Med 24, P1905, 2016
32016
Improved deep gray matter segmentation using anatomical information from quantitative susceptibility maps
F Schweser, X Feng, RM Batlle, D Güllmar, A Deistung, MG Dwyer, ...
Milan 22, 1787, 2014
32014
High resolution dynamic cardiac MRI using partial separability of spatiotemporal signals with a novel sampling scheme
G Xie, X Feng, AG Christodoulou, D Weng, X Liu, B Qiu
Magnetic resonance imaging 31 (4), 529-537, 2013
32013
Etiologic classification of infantile spasms using positron emission/magnetic resonance imaging and the efficacy of adrenocorticotropic hormone therapy
H Dang, L Zou, J Tian, J Liu, X Feng, M Lin, B Xu
European Journal of Nuclear Medicine and Molecular Imaging, 1-11, 2020
12020
Image Quality Improvement by Applying Retrospective Motion Correction on Quantitative Susceptibility Mapping and R2
X Feng, A Loktyushin, A Deistung, J Reichenbach
25th Annual Meeting and Exhibition of the International Society for Magnetic …, 2017
12017
Investigation of Brain Tissue Fixation on Iron Concentration, Magnetic Susceptibility and Effective Transverse Relaxation Rate
A Deistung, V Endmayr, S Hametner, M Prihoda, X Feng, H Lassmann, ...
Intl Soc Mag Reson Med, 22-27, 2017
12017
A kernel method for higher temporal resolution MRI using the partial separability (PS) model
X Feng, G Xie, X Liu, B Qiu
Biomedical Engineering/Biomedizinische Technik 61 (4), 393-400, 2016
12016
PSF model simulation study using a cardiac phantom
X Feng, G Xie, S He, YC Chung, D Liang, X Liu, B Qiu
2011 4th International Conference on Biomedical Engineering and Informatics …, 2011
12011
A simulation study of dynamic MRI based on partially separable functions and keyhole techniques
GX Xie, Z Weng, C Zou, X Feng, HR Zheng, X Liu, B Qiu
2011 4th International Conference on Biomedical Engineering and Informatics …, 2011
12011
Improved Dynamic Imaging with PS-Model-Based Sparse Sampling
X Feng, G Xie, C Zou, AG Christodoulou, X Liu, B Qiu
Proc. Intl. Soc. Mag. Reson. Med 64, 1162-1170, 2010
12010
Which parameters are optimal?-A comprehensive numerical analysis of background phase correction with SHARP
F Schweser, PS Özbay, A Deistung, EDP Gomez, X Feng, D Nanz, ...
Neuron 33 (3), 341-55, 2002
12002
Evaluating cervical artery dissections in young adults: a comparison study between high-resolution MRI and CT angiography
X Yuan, X Cui, H Gu, M Wang, Y Dong, S Cai, X Feng, X Wang
The International Journal of Cardiovascular Imaging, 1-7, 2020
2020
The system can't perform the operation now. Try again later.
Articles 1–20