Silvia Mazzocchi
Silvia Mazzocchi
USL Toscana Centro
Email verificata su uslcentro.toscana.it
Titolo
Citata da
Citata da
Anno
Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size
M Bucciolini, F Banci Buonamici, S Mazzocchi, C De Angelis, S Onori, ...
Medical physics 30 (8), 2149-2154, 2003
1732003
An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams
C De Angelis, S Onori, M Pacilio, GAP Cirrone, G Cuttone, L Raffaele, ...
Medical physics 29 (2), 248-254, 2002
1082002
Quality assurance multicenter comparison of different MR scanners for quantitative diffusion‐weighted imaging
G Belli, S Busoni, A Ciccarone, A Coniglio, M Esposito, M Giannelli, ...
Journal of Magnetic Resonance Imaging 43 (1), 213-219, 2016
782016
Characterisation of CVD diamond dosimeters in on-line configuration
M Bruzzi, M Bucciolini, GAP Cirrone, G Cuttone, S Mazzocchi, S Pirollo, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2000
462000
Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position–A quality assurance intercomparison study of forty-four scanners …
L Fedeli, G Belli, A Ciccarone, A Coniglio, M Esposito, M Giannelli, ...
Physica Medica 55, 135-141, 2018
292018
Characterization of CVD diamond films as radiation detectors for dosimetric applications
M Bruzzi, M Bucciolini, GAP Cirrone, G Cuttone, A Guasti, S Mazzocchi, ...
1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science …, 1999
231999
Use of TLD in evaluating diagnostic reference levels for some radiological examinations
D Berni, C Gori, B Lazzari, S Mazzocchi, F Rossi, G Zatelli
Radiation protection dosimetry 101 (1-4), 411-413, 2002
212002
Thermoluminescence characterisation of chemical vapour deposited diamond films
S Mazzocchi, M Bruzzi, M Bucciolini, G Cuttone, S Pini, MG Sabini, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002
202002
TSC response of irradiated CVD diamond films
E Borchi, M Bruzzi, M Bucciolini, A Guasti, S Mazzocchi, S Pirollo, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1999
181999
AEC set-up optimisation with computed radiography imaging
S Mazzocchi, G Belli, S Busoni, C Gori, I Menchi, P Salucci, A Taddeucci, ...
Radiation protection dosimetry 117 (1-3), 169-173, 2005
172005
On the dependence of quantitative diffusion-weighted imaging on scanner system characteristics and acquisition parameters: A large multicenter and multiparametric phantom study …
L Fedeli, M Benelli, S Busoni, G Belli, A Ciccarone, A Coniglio, M Esposito, ...
Physica Medica 85, 98-106, 2021
152021
A comparison study of radiation exposure to patients during EVAR and Dyna CT in an angiosuite vs. an operating theatre
A Bruschi, S Michelagnoli, E Chisci, S Mazzocchi, S Panci, A Didona, ...
Radiation Protection Dosimetry 163 (4), 491-498, 2015
132015
TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects
MG Sabini, M Bucciolini, G Cuttone, A Guasti, S Mazzocchi, L Raffaele
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002
132002
The CANDIDO project: development of a CVD diamond dosimeter for applications in radiotherapy
G Cuttone, L Azario, LB Tonghi, E Borchi, D Boscarino, M Bruzzi, ...
Nuclear Physics B-Proceedings Supplements 78 (1-3), 587-591, 1999
131999
The incremental value of computed tomography of COVID-19 pneumonia in predicting ICU admission
M Bartolucci, M Benelli, M Betti, S Bicchi, L Fedeli, F Giannelli, D Aquilini, ...
Scientific Reports 11 (1), 15619, 2021
82021
The use of thermoluminescent detectors for measurements of proton dose distribution
M G. Sabini, L Raffaele, M Bucciolini, G AP Cirrone, G Cuttone, S Lo Nigro, ...
Radiation protection dosimetry 101 (1-4), 453-456, 2002
82002
An operational approach to the execution of MR examinations in patients with CIED
L Guerrini, S Mazzocchi, A Giomi, M Milli, R Carpi
La radiologia medica 125, 1311-1321, 2020
72020
A comparison of the TLD-100 response to 60 Co beam and 62 MeV protons
M Bucciolini, G Cuttone, E Egger, A Guasti, S Mazzocchi, L Raffaele, ...
Physica Medica 15, 71-77, 1999
61999
A study of feasibility of dose reduction in paediatric MSCT scanning with a constant image quality
G Zatelli, A Ciccarone, S Mazzocchi, C Fonda
Physica Medica 24 (2), 107-111, 2008
32008
Thermoluminescence CVD diamond films for dosimetric applications
S Mazzocchi, M Bruzzi, M Bucciolini, G Cuttone, A Guasti, S Pini, ...
PHYSICA MEDICA 17, 45-48, 2001
32001