Luigi La Barbera, Ph.D.
Luigi La Barbera, Ph.D.
École Polytechnique de Montréal, CHU Sainte-Justine, Canada
Verified email at polymtl.ca
Title
Cited by
Cited by
Year
Instrumentation failure following pedicle subtraction osteotomy: the role of rod material, diameter, and multi-rod constructs
A Luca, C Ottardi, M Sasso, L Prosdocimo, L La Barbera, M Brayda-Bruno, ...
European Spine Journal 26 (3), 764-770, 2017
352017
Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems
T Villa, L La Barbera, F Galbusera
The Spine Journal 14 (4), 695-704, 2014
352014
Primary stability of pedicle screws depends on the screw positioning and alignment
F Costa, T Villa, F Anasetti, M Tomei, A Ortolina, A Cardia, L La Barbera, ...
The Spine Journal 13 (12), 1934-1939, 2013
292013
ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?
L La Barbera, F Galbusera, T Villa, F Costa, HJ Wilke
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014
222014
Does soccer cleat design influence the rotational interaction with the playing surface?
F Galbusera, DZ Tornese, F Anasetti, S Bersini, P Volpi, LL Barbera, ...
Sports biomechanics 12 (3), 293-301, 2013
212013
Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189
L La Barbera, C Ottardi, T Villa
The Spine Journal 15 (10), 2290-2296, 2015
192015
Preclinical evaluation of posterior spine stabilization devices: can the current standards represent basic everyday life activities?
L La Barbera, F Galbusera, HJ Wilke, T Villa
European Spine Journal 25 (9), 2909-2918, 2016
162016
Performances analysis of titanium prostheses manufactured by superplastic forming and incremental forming
G Ambrogio, E Sgambitterra, L De Napoli, F Gagliardi, G Fragomeni, ...
Procedia Engineering 183, 168-173, 2017
132017
ISO 12189 standard for the preclinical evaluation of posterior spinal stabilization devices–I: Assembly procedure and validation
L La Barbera, T Villa
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016
132016
Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy
L La Barbera, M Brayda-Bruno, C Liebsch, T Villa, A Luca, F Galbusera, ...
European Spine Journal 27 (9), 2357-2366, 2018
112018
Preclinical evaluation of posterior spine stabilization devices: can we compare in vitro and in vivo loads on the instrumentation?
L La Barbera, F Galbusera, HJ Wilke, T Villa
European Spine Journal 26 (1), 200-209, 2017
102017
ISO 12189 standard for the preclinical evaluation of posterior spinal stabilization devices–II: a parametric comparative study
L La Barbera, F Costa, T Villa
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016
102016
Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis
A Cianfoni, D Distefano, E Pravatà, V Espeli, G Pesce, P Mordasini, ...
Journal of neurointerventional surgery 11 (3), 313-318, 2019
92019
Planning the surgical correction of spinal deformities: toward the identification of the biomechanical principles by means of numerical simulation
F Galbusera, T Bassani, L La Barbera, C Ottardi, B Schlager, ...
Frontiers in bioengineering and biotechnology 3, 178, 2015
92015
Toward the definition of a new worst-case paradigm for the preclinical evaluation of posterior spine stabilization devices
L La Barbera, T Villa
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2017
82017
Vertebroplasty and kyphoplasty for the treatment of thoracic fractures in osteoporotic patients: a finite element comparative analysis
C Ottardi, L La Barbera, L Pietrogrande, T Villa
Journal of applied biomaterials & functional materials 14 (2), 197-204, 2016
82016
Rotational and peak torque stiffness of rugby shoes
MS Ballal, FG Usuelli, UA Montrasio, A Molloy, L La Barbera, T Villa, ...
The Foot 24 (3), 107-110, 2014
62014
Stent Screw− Assisted Internal Fixation (SAIF) of Severe Lytic Spinal Metastases: A Comparative Finite Element Analysis of the SAIF Technique
L La Barbera, A Cianfoni, A Ferrari, D Distefano, G Bonaldi, T Villa
World neurosurgery 128, e370-e377, 2019
42019
Residual stresses in titanium spinal rods: effects of two contouring methods and material plastic properties
F Berti, L La Barbera, A Piovesan, D Allegretti, C Ottardi, T Villa, G Pennati
Journal of Biomechanical Engineering 140 (11), 2018
42018
Reply to the letter to the editor entitled: Response to “Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems”
T Villa, L La Barbera, F Galbusera
The Spine Journal 14 (12), 3068, 2014
42014
The system can't perform the operation now. Try again later.
Articles 1–20