Maria Ida Iacono
Maria Ida Iacono
Verified email at fda.hhs.gov
Title
Cited by
Cited by
Year
MIDA: a multimodal imaging-based detailed anatomical model of the human head and neck
MI Iacono, E Neufeld, E Akinnagbe, K Bower, J Wolf, IV Oikonomidis, ...
PloS one 10 (4), e0124126, 2015
1162015
A multi-tissue mass-spring model for computer assisted breast surgery
P Patete, MI Iacono, MF Spadea, G Trecate, D Vergnaghi, LT Mainardi, ...
Medical engineering & physics 35 (1), 47-53, 2013
392013
Local SAR near deep brain stimulation (DBS) electrodes at 64 and 127 MH z: A simulation study of the effect of extracranial loops
L Golestanirad, LM Angelone, MI Iacono, H Katnani, LL Wald, ...
Magnetic resonance in medicine 78 (4), 1558-1565, 2017
352017
Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants
L Golestanirad, MI Iacono, B Keil, LM Angelone, G Bonmassar, MD Fox, ...
Neuroimage 147, 577-588, 2017
352017
RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management
L Golestanirad, J Kirsch, G Bonmassar, S Downs, B Elahi, A Martin, ...
Neuroimage 184, 566-576, 2019
292019
MRI-based multiscale model for electromagnetic analysis in the human head with implanted DBS
MI Iacono, N Makris, L Mainardi, LM Angelone, G Bonmassar
Computational and mathematical methods in medicine 2013, 2013
262013
Numerical simulations of realistic lead trajectories and an experimental verification support the efficacy of parallel radiofrequency transmission to reduce heating of deep …
CE McElcheran, L Golestanirad, MI Iacono, PS Wei, B Yang, ...
Scientific reports 9 (1), 1-14, 2019
192019
Assessing the electromagnetic fields generated by a radiofrequency MRI body coil at 64 MHz: defeaturing vs. accuracy
E Lucano, M Liberti, G Mendoza, T Lloyd, MI Iacono, F Apollonio, ...
IEEE Transactions on Biomedical Engineering, 2015
192015
Retrospective analysis of RF heating measurements of passive medical implants
T Song, Z Xu, MI Iacono, LM Angelone, S Rajan
Magnetic Resonance in Medicine 80 (6), 2726-2730, 2018
182018
Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies
B Guerin, P Serano, MI Iacono, TM Herrington, AS Widge, DD Dougherty, ...
Physics in Medicine & Biology 63 (9), 095015, 2018
162018
Biomimetic 3D-printed neurovascular phantoms for near-infrared fluorescence imaging
Y Liu, P Ghassemi, A Depkon, MI Iacono, J Lin, G Mendoza, J Wang, ...
Biomedical optics express 9 (6), 2810-2824, 2018
152018
Investigation of assumptions underlying current safety guidelines on EM-induced nerve stimulation
E Neufeld, IV Oikonomidis, MI Iacono, LM Angelone, W Kainz, N Kuster
Physics in Medicine & Biology 61 (12), 4466, 2016
152016
Radio-Frequency Safety Assessment of Stents in Blood Vessels During Magnetic Resonance Imaging
K Fujimoto, LM Angelone, E Lucano, SS Rajan, MI Iacono
Frontiers in physiology 9, 1439, 2018
102018
Parallel transmission for heating reduction in realistic deep brain stimulation lead trajectories
C McElcheran, L Golestanirad, M Iacono, B Yang, K Anderson, ...
Proc. Intl. Soc. Mag. Reson. Med 25, 2017
92017
Computational platform combining detailed and precise functionalized anatomical phantoms with EM-Neuron interaction modeling
E Neufeld, MI Iacono, E Akinnagbe, J Wolf, IV Oikonomidis, D Sharma, ...
2014 XXXIth URSI General Assembly and Scientific Symposium (URSI GASS), 1-4, 2014
62014
A computational model for bipolar deep brain stimulation of the subthalamic nucleus
MI Iacono, E Neufeld, G Bonmassar, E Akinnagbe, A Jakab, E Cohen, ...
2014 36th Annual International Conference of the IEEE Engineering in …, 2014
52014
Atlas-based segmentation for globus pallidus internus targeting on low-resolution MRI
MI Iacono, N Makris, L Mainardi, J Gale, A Van Der Kouwe, A Mareyam, ...
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
52011
The ‘virtual DBS population’: five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies
B Guerin, MI Iacono, M Davids, D Dougherty, LM Angelone, LL Wald
Physics in Medicine & Biology 64 (3), 035021, 2019
42019
Low heating B1 mapping in parallel transmit for deep brain stimulators
C McElcheran, L Golestanirad, M Iacono, B Yang, K Anderson, ...
Proc. Intl. Soc. Mag. Reson. Med 25, 2017
42017
Simulation platform for coupled modeling of EM-induced neuronal dynamics and functionalized anatomical models
E Neufeld, IV Oikonomidis, MI Iacono, E Akinnagbe, LM Angelone, ...
2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), 517-520, 2015
42015
The system can't perform the operation now. Try again later.
Articles 1–20